Main Technical Specifications
Item | Specifications |
Impact Energy | 500 J / 250 J |
Dial Scale Range & Graduation: | |
- Energy Range | 0–500 J / 0–250 J |
- Graduation per Division | 5 J / 2.5 J |
Pendulum Moment of Force: | |
- 500 J Pendulum | 267.9492 N·m |
- 250 J Pendulum | 133.9746 N·m |
Pre-Raise Angle of Pendulum | 150° ± 1° |
Distance from Pendulum Axis to Specimen Center | 800 mm |
Impact Speed | 5.4 m/s |
Span of Anvils | 40 mm |
Radius of Anvil Edge | R1–1.5 mm |
Radius of Impact Edge | R2–2.5 mm |
Impact Blade Angle | 30° ± 1° |
Impact Blade Thickness | 16 mm |
Specimen Dimensions | 10 × 10 × 55 mm |
Machine Weight | Approx. 550 kg |
Max Overall Dimensions | 2100 × 650 × 1960 mm |
Power Supply | Three-phase four-wire, 50 Hz, 380 V, 180 W (main motor) |
Operating Conditions
a. Ambient temperature: 10°C – 35°C
b. Relative humidity: ≤ 85%
c. Free from corrosive media in the surrounding environment
d. Must be installed on a concrete foundation no less than 200 mm thick, or anchored to a base weighing more than 1000 kg
e. The levelness of the reference plane on the base must be adjusted to within 0.2/1000